Industrial hot-air dry roasting in the nut processing sector is characterized by high specific thermal energy consumption and significant low energy efficiency ratio, mainly due to direct air heating and limited recovery of waste heat from exhaust streams. This study investigates the work condition design and integration of a high temperature heat pump system for waste heat recovery and process air preheating in an industrial gas-fed hot-air roasting plant; Moreover it aims to evaluate the complete replacing of traditional thermal source with heat pump use through a required primary energy reduction. The hot and humid exhaust air flow from the drying section is directed onto the heat exchanger of a high temperature heat pump. Both sensible and most important latent heat are then recovered to keep the cold sink of the heat pump warm enough to reduce the temperature leap from the two heat sinks, thus optimizing the size of the compressor to eventually increase the COP of the system. A dry roaster case study is considered and two temperature interval scenarios are evaluated. R1233zd_e is considered as the main refrigerant fluid due to its versatility and current state of the art commercial use. Optimal refrigerant mass flow rate is then evaluated in relation to the nut roasting process requirements. The investigation aims to lead to a significant attention raise in high temperature heat pump use for medium temperature application (below 200°C) such as roasting where a hot and humid exhaust flow rate is available throughout the production cycle due to the main task of the process itself: decrease moisture from the main product that is eventually exhausted and available outside the drying/roasting chamber. The study underlines that, under the considered fluid and process assumptions, it is possible to recover from approximately 33 % to about 39 % of the burner thermal demand at the hot sink — depending on whether the heat pump is designed for a conservative (Tcond = 80 °C) or frontier (Tcond = 110 °C) condensation temperature, and accounting for air-side heat-exchanger efficiencies of 0.90. This pre-heating effect reduces the natural gas consumption and, when the compressor is supplied by an on-site photovoltaic plant in self-consumption, leads to an overall specific primary-energy reduction of approximately 65 Wh/kg of inlet product against a baseline thermal-energy requirement of about 168 Wh/kg derived from process assumptions for industrial hazelnut dry-roasting.

Integration of high-temperature heat pumps in industrial nut roasting: Psychrometric assessment for exhaust waste heat recovery application and primary energy requirement reduction / Mirandola, S., Ruini, L., Santangelo, P.E., Muscio, A.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6596. - 3351:1(2026). (ATI Annual Congress 2026 09/09/2026 - 11/09/2026 Milan, Italy Milan, Italy 9-11 settembre 2026) [10.1088/1742-6596/3351/1/012034].

Integration of high-temperature heat pumps in industrial nut roasting: Psychrometric assessment for exhaust waste heat recovery application and primary energy requirement reduction

Santangelo, Paolo Emilio;Muscio, Alberto
2026

Abstract

Industrial hot-air dry roasting in the nut processing sector is characterized by high specific thermal energy consumption and significant low energy efficiency ratio, mainly due to direct air heating and limited recovery of waste heat from exhaust streams. This study investigates the work condition design and integration of a high temperature heat pump system for waste heat recovery and process air preheating in an industrial gas-fed hot-air roasting plant; Moreover it aims to evaluate the complete replacing of traditional thermal source with heat pump use through a required primary energy reduction. The hot and humid exhaust air flow from the drying section is directed onto the heat exchanger of a high temperature heat pump. Both sensible and most important latent heat are then recovered to keep the cold sink of the heat pump warm enough to reduce the temperature leap from the two heat sinks, thus optimizing the size of the compressor to eventually increase the COP of the system. A dry roaster case study is considered and two temperature interval scenarios are evaluated. R1233zd_e is considered as the main refrigerant fluid due to its versatility and current state of the art commercial use. Optimal refrigerant mass flow rate is then evaluated in relation to the nut roasting process requirements. The investigation aims to lead to a significant attention raise in high temperature heat pump use for medium temperature application (below 200°C) such as roasting where a hot and humid exhaust flow rate is available throughout the production cycle due to the main task of the process itself: decrease moisture from the main product that is eventually exhausted and available outside the drying/roasting chamber. The study underlines that, under the considered fluid and process assumptions, it is possible to recover from approximately 33 % to about 39 % of the burner thermal demand at the hot sink — depending on whether the heat pump is designed for a conservative (Tcond = 80 °C) or frontier (Tcond = 110 °C) condensation temperature, and accounting for air-side heat-exchanger efficiencies of 0.90. This pre-heating effect reduces the natural gas consumption and, when the compressor is supplied by an on-site photovoltaic plant in self-consumption, leads to an overall specific primary-energy reduction of approximately 65 Wh/kg of inlet product against a baseline thermal-energy requirement of about 168 Wh/kg derived from process assumptions for industrial hazelnut dry-roasting.
2026
ATI Annual Congress 2026 09/09/2026 - 11/09/2026 Milan, Italy
Milan, Italy
9-11 settembre 2026
3351
Mirandola, Saverio; Ruini, Lorenzo; Santangelo, Paolo Emilio; Muscio, Alberto
Integration of high-temperature heat pumps in industrial nut roasting: Psychrometric assessment for exhaust waste heat recovery application and primary energy requirement reduction / Mirandola, S., Ruini, L., Santangelo, P.E., Muscio, A.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6596. - 3351:1(2026). (ATI Annual Congress 2026 09/09/2026 - 11/09/2026 Milan, Italy Milan, Italy 9-11 settembre 2026) [10.1088/1742-6596/3351/1/012034].
File in questo prodotto:
File Dimensione Formato  
Mirandola_JPCS_2026.pdf

Open access

Tipologia: VOR - Versione pubblicata dall'editore
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1425448
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact