This study investigates the application of a portable near-infrared (NIR) spectrometer for real-time, in-situ monitoring of milk coagulation within a process analytical technology (PAT) framework. Coagulation trials were carried out in laboratory using raw milk and natural whey starter under controlled conditions, applying three coagulants (one calf rennet and two coagulants from Rhizomucor miehei cultures) according to a full factorial experimental design. Continuous NIR spectra (900–1700 nm) were collected through a food-grade probe and arranged in a three-way array (experiments × wavelengths × time). Multilinear partial least squares (NPLS) models were developed to relate spectral evolution to reference lactodynamograph parameters, enabling prediction of curd firming rate (k20) and curd firmness (a30). Sequential NPLS modelling further allowed assessing real-time applicability. Results demonstrate that compact NIR sensors, combined with multiway chemometrics, offer a robust and non-invasive strategy for monitoring coagulation kinetics, supporting more consistent curd-cutting decisions and improved cheesemaking control.

A multiway approach to monitoring Milk coagulation by NIR in situ / Benedini, Dario; Strani, Lorenzo; Cocchi, Marina; Cabassi, Giovanni. - In: MICROCHEMICAL JOURNAL. - ISSN 0026-265X. - 225:(2026), pp. 118217-118225. [10.1016/j.microc.2026.118217]

A multiway approach to monitoring Milk coagulation by NIR in situ

Benedini, Dario;Strani, Lorenzo
;
Cocchi, Marina;
2026

Abstract

This study investigates the application of a portable near-infrared (NIR) spectrometer for real-time, in-situ monitoring of milk coagulation within a process analytical technology (PAT) framework. Coagulation trials were carried out in laboratory using raw milk and natural whey starter under controlled conditions, applying three coagulants (one calf rennet and two coagulants from Rhizomucor miehei cultures) according to a full factorial experimental design. Continuous NIR spectra (900–1700 nm) were collected through a food-grade probe and arranged in a three-way array (experiments × wavelengths × time). Multilinear partial least squares (NPLS) models were developed to relate spectral evolution to reference lactodynamograph parameters, enabling prediction of curd firming rate (k20) and curd firmness (a30). Sequential NPLS modelling further allowed assessing real-time applicability. Results demonstrate that compact NIR sensors, combined with multiway chemometrics, offer a robust and non-invasive strategy for monitoring coagulation kinetics, supporting more consistent curd-cutting decisions and improved cheesemaking control.
2026
28-apr-2026
225
118217
118225
A multiway approach to monitoring Milk coagulation by NIR in situ / Benedini, Dario; Strani, Lorenzo; Cocchi, Marina; Cabassi, Giovanni. - In: MICROCHEMICAL JOURNAL. - ISSN 0026-265X. - 225:(2026), pp. 118217-118225. [10.1016/j.microc.2026.118217]
Benedini, Dario; Strani, Lorenzo; Cocchi, Marina; Cabassi, Giovanni
File in questo prodotto:
File Dimensione Formato  
MICROC-D-26-03070_R1-9-30.pdf

embargo fino al 28/04/2028

Tipologia: AAM - Versione dell'autore revisionata e accettata per la pubblicazione
Dimensione 2.66 MB
Formato Adobe PDF
2.66 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1403912
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact