Contactless vital signs monitoring is becoming increasingly relevant in scenarios where conventional sensors are impractical or not recommended. In this manuscript, a radar-based contactless system for the joint reconstruction of phonocardiogram (PCG) waveforms and cardiac state segmentation is illustrated. The proposed method exploits a self-attention one-dimensional (1D) U-Net fed by a pre-processed radar-derived input to estimate a PCG-like waveform, its envelope, and the four main cardiac phases: S1, systole, S2, and diastole. The accuracy of our method has been assessed on a public synchronized radar–PCG dataset acquired by means of a 24 GHz Doppler radar and a digital stethoscope. On the test subset, the proposed model achieved a 13.4885 dB reduction in log-spectral distance relative to the radar input signal, indicating a marked improvement in waveform fidelity. Segmentation performance also improved, with Micro-F1 increasing from 74.41% to 84.17% and Macro-F1 from 68.40% to 80.43% on average. Experimental results demonstrated the viability of real-time low-power embedded hardware deployment for contactless auscultation and continuous cardiac monitoring applications. The findings confirm that respiratory interference and low-amplitude signals complicate S2 detection, especially when exacerbated by subject motion.

A Radar-Based Contactless System for Joint Phonocardiogram Reconstruction and Cardiac State Segmentation Using a Self-Attention 1D U-Net / Montanari, Giulio; Mura, Marco; Di Viesti, Pasquale; Vignoli, Elia; Guerzoni, Giorgio; Vitetta, Giorgio Matteo. - In: SENSORS. - ISSN 1424-8220. - 26:10(2026), pp. 1-23. [10.3390/s26103151]

A Radar-Based Contactless System for Joint Phonocardiogram Reconstruction and Cardiac State Segmentation Using a Self-Attention 1D U-Net

Montanari, Giulio;Mura, Marco;Di Viesti, Pasquale;Vignoli, Elia;Guerzoni, Giorgio;Vitetta, Giorgio Matteo
2026

Abstract

Contactless vital signs monitoring is becoming increasingly relevant in scenarios where conventional sensors are impractical or not recommended. In this manuscript, a radar-based contactless system for the joint reconstruction of phonocardiogram (PCG) waveforms and cardiac state segmentation is illustrated. The proposed method exploits a self-attention one-dimensional (1D) U-Net fed by a pre-processed radar-derived input to estimate a PCG-like waveform, its envelope, and the four main cardiac phases: S1, systole, S2, and diastole. The accuracy of our method has been assessed on a public synchronized radar–PCG dataset acquired by means of a 24 GHz Doppler radar and a digital stethoscope. On the test subset, the proposed model achieved a 13.4885 dB reduction in log-spectral distance relative to the radar input signal, indicating a marked improvement in waveform fidelity. Segmentation performance also improved, with Micro-F1 increasing from 74.41% to 84.17% and Macro-F1 from 68.40% to 80.43% on average. Experimental results demonstrated the viability of real-time low-power embedded hardware deployment for contactless auscultation and continuous cardiac monitoring applications. The findings confirm that respiratory interference and low-amplitude signals complicate S2 detection, especially when exacerbated by subject motion.
2026
mag-2026
26
10
1
23
A Radar-Based Contactless System for Joint Phonocardiogram Reconstruction and Cardiac State Segmentation Using a Self-Attention 1D U-Net / Montanari, Giulio; Mura, Marco; Di Viesti, Pasquale; Vignoli, Elia; Guerzoni, Giorgio; Vitetta, Giorgio Matteo. - In: SENSORS. - ISSN 1424-8220. - 26:10(2026), pp. 1-23. [10.3390/s26103151]
Montanari, Giulio; Mura, Marco; Di Viesti, Pasquale; Vignoli, Elia; Guerzoni, Giorgio; Vitetta, Giorgio Matteo
File in questo prodotto:
File Dimensione Formato  
sensors-26-03151-v2.pdf

Open access

Tipologia: VOR - Versione pubblicata dall'editore
Licenza: [IR] creative-commons
Dimensione 1.99 MB
Formato Adobe PDF
1.99 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1407328
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact